USystems is the preferred supplier of server cabinets and frames (24U, 30U, 36U, 42U & 48U), including all compatible shelves, fans, fittings and accessories.
Eaton Williams and USystems have developed a water cooling system - ColdLogik that uses less power, creates less heat and can work with your current systems.
 
 

24U Cabinets/Frames

24U cabinets and frames, including all compatible shelves, fans, fittings and accessories. More »

30U Cabinets/Frames

30U cabinets and frames, including all compatible shelves, fans, fittings and accessories. More »
 
 
 
 

36U Cabinets/Frames

36U cabinets and frames, including all compatible shelves, fans, fittings and accessories More »

42U Cabinets/Frames

42U cabinets and frames, including all compatible shelves, fans, fittings and accessories. More »
 
 
 
 

48U Cabinets/Frames

48U cabinets and frames, including all compatible shelves, fans, fittings and accessories. More »
Accessories
Including fixed and extendable plinths, cable management, document wallets, depth support rails, blanking panels, baying kits, cage nut fixings, jumper rings hanging brackets, power strips, mounting angles and bonding kits. More >
 
 
ColdLogik™ Cooling Systems

High Density Cooling Solutions from USystems

In conjunction with Eaton Williams, a leading global cooling specialist in high tech applications, USystems have developed a range of cooling solutions to meet the ever increasing heat demands placed upon data centres and offices in general.

Problem: Heat Issues with Data Centres - Modular Range of Solutions

Conventional cabinet design allows heat from the equipment to pass straight back into the room.

cl20front ColdLogik CL20 -
Fully Vented Front
  cl20rear ColdLogik CL20 -
Rear Door Heat Exchanger

air flow
  • Rising heat densities
  • Limitations per tile of 2-3kw's
  • Shortened life expectancy for equipment
  • Equipment failure - cost of replacement and loss of revenue
  • Rising energy costs

Solution 1: The ColdLogik™ CL20 Rear Door Heat Exchanger

Hot air produced by the equipment is pulled across a coil housed within the rear door, during the process the temperature of the air is reduced back down to the ambient room temperature. Because the coil covers the whole of the rear door the pull is even and therefore "hot spots" don't occur. Furthermore balance is maintained within the room thus eliminating hot zones.

airflow2
  • High density racks can be implemented without upgrading
  • Lower energy use
  • Cheaper to run than conventional AC
  • Eradicate 'hot spots' with precision cooling
  • Full rack space available
  • Zero thermal impact
  • A/C can be planned with no more real estate requirements
  • Modular - expand the system as you go
  • Space - water can absorb 3,500 times more heat than air
  • Built in redundancy
  • Remote monitoring available
A curtain of cold air is forced down the front face of the cabinet CL5 Coil and Fan Unit   Utilising and redirecting cold air from a raised floor CL Plenum Unit

Solution 2: The ColdLogik™ CL50 Cooling Distribution Unit

CL150 Cooling Distribution Unit

The CL150 CDU will supply up to six rear door heat exchangers with clean, cooled water at a constant flow rate within a sealed and pressurised circuit. Supply water can be set to a fixed temperature or to 'dew point tracking' to maximise available cooling without fear of condensation at the rack.

For further details on the ColdLogik™ product range please contact our sales department, or download the ColdLogik™ Information Sheet below: